(84 products available)
The Neubauer improved is a type of hemocytometer, a device used to count cells, especially in blood. The Neubauer improved hemocytometer has a 1 mm² grid etched into its glass, which allows for more accurate cell counting. It also has a double grid, which makes it easier to use and less likely to lose count.
Another advantage of the new and improved Neubauer hemocytometer is that the counting chamber is 0.1 mm deep, which allows a volume of 0.1 µL to be counted. This feature is particularly important for counting low-density cell populations. The Neubauer improved hemocytometer is also made of a special type of glass that is less likely to attract dust and debris, which can interfere with cell counting and give inaccurate results.
There are two types of hemocytometers: the Unopette hemocytometer and the improved Neubauer hemocytometer. The former is the most commonly used type of hemocytometer. It is made of a thick glass slide with a rectangular indentation in the middle. The counting chamber is 0.1 mm deep, and a grid is etched into the glass to facilitate cell counting. The Neubauer improved hemocytometer is a modification of the Unopette hemocytometer. It has a number of improvements over the original design, including a more durable construction and an easier-to-use counting grid.
Another type of hemocytometer is the Bright-Line hemocytometer. This type of hemocytometer has a line etched into the glass. The line is thicker and darker than the other lines, and it is easier to see. The main advantage of the Bright-Line hemocytometer is that it is easier to use for people with vision problems.
A Neubauer Improved counting chamber has the following specifications:
A Neubauer Improved counting chamber is typically made of glass. It is composed of two optical section ruling surfaces, which are usually etched into the glass. The material of the chamber ensures that the device is transparent and allows the user to observe and count objects under a microscope.
The volume of the counting chamber is an important specification. It is used to hold the liquid sample to be counted. The volume of the chamber is usually 0.1 microliters, which is marked by a grid. The specific volume is designed to meet the needs of different types of cell counting and to ensure the accuracy of the results.
The grid pattern of the counting chamber is also an important specification. It is used to help the user count the objects in the sample. The Neubauer Improved counting chamber is often marked with a 3x3 grid pattern. The grid consists of various squares, rectangles, or lines, which help the user to accurately determine the number of objects in the sample. The specific grid pattern is designed to adapt to different counting objects and ensure the accuracy of the counting results.
The calibration of the counting chamber is an important specification. It sets the traceability of the device to the national standard. The calibration is usually done by the manufacturer. It is usually performed using specific object samples, and the counting results are compared with the national standard to ensure the accuracy and reliability of the counting chamber.
The maintenance of the counting chamber is important, which can ensure the accuracy and reliability of the counting results. Here are some tips for the maintenance of the Neubauer Improved counting chamber:
After using the counting chamber, users should clean it in time to remove the residue that may be on the surface. They can use clean water or a mild cleaning solution to gently rinse the chamber. When cleaning, people should avoid using rough materials or chemicals to prevent damage to the chamber.
After cleaning, users should air dry the counting chamber. It is important to ensure that there is no residue left on the surface. Avoid exposing the chamber to direct sunlight or high temperatures, which may cause deformation or damage.
When not in use, the counting chamber should be stored in a clean and dry place. Users should avoid placing it in a humid or dusty environment to prevent contamination. In addition, users can cover the chamber with a protective cover to prevent damage or scratches.
There are various applications for a Neubauer Improved counting chamber. The following are some of the most common applications to be aware of:
In the medical field, the Neubauer Improved counting chamber can be used to determine the number of cells in a specific volume of fluid. This may include counting blood cells, urine cells, or even cerebrospinal fluid cells. The results gathered from this process can be used to diagnose various medical conditions and help medical practitioners come up with treatment plans.
In biological research, the Neubauer Improved counting chamber can be used to count the number of microorganisms present in a sample. This may include bacteria, algae, or even yeast. The results gathered from this process can be used to study the growth rate of the microorganisms and how they respond to different environmental factors.
A Neubauer Improved counting chamber can be used in the food and beverage industry to check for food contamination. It can be used to count the number of bacteria present in a sample of food. This can help food manufacturers ensure that their products are safe for consumption.
In the manufacturing industry, the Neubauer Improved counting chamber can be used to ensure the quality of products. It can be used to count the number of particles present in a specific volume. This can include counting dust particles, paint pigment, or even cell particles. The results gathered from this process can help manufacturers make the necessary adjustments to ensure that their products meet the required standards.
When it comes to selecting products, it is helpful to first think about the end customers and what their needs are. Consider the types of laboratories that are looking to purchase a Neubauer improved hemocytometer. Are they medical institutions, research institutions, or industrial companies with labs? Each type of lab has different needs, and therefore, the type of hemocytometer needed will vary. For example, a hospital may want a Neubauer improved hemocytometer that is more durable and is able to withstand heavy use. On the other hand, a research university may require a more precise and accurate hemocytometer. Take the time to get to know the target customers and their needs so that the best type of hemocytometer is purchased.
Another important factor to consider is the brand of the hemocytometer. It is crucial to work with a supplier that offers reputable and high-quality brands. Customers will want to purchase from a brand they know and trust. Look for a supplier that has a good reputation and offers quality products. Additionally, it is important to consider the supplier's service and support. Customers will want to work with a supplier that is reliable and offers good customer support. Look for a supplier that offers fast shipping and great customer service. It can also be helpful to look for a supplier that offers product training and resources.
Pay close attention to the specifications of the hemocytometer. Consider the kind of cell that will be used with it and make sure it is compatible with the hemocytometer. The accuracy of the hemocytometer is vital for the correct functioning of the cell counter and the treatment of the patient. It is also important to consider the hemocytometer's quality and any relevant certifications. Hemocytometers should be made with materials that are durable and resistant to breaking. They are also coated with substances that do not interfere with cell counting accuracy. For example, the hemocytometer glass is coated with a platinum film, which allows for the even distribution of cells on the grid lines.
Q1: How does a Neubauer improved hemocytometer work?
A1: The chamber is divided into nine squares. Each large square is 1mm x 1mm and has an approximate depth of 0.1mm. By counting cells in these squares and using a specific equation, it is possible to determine the number of cells in 1 μl or 1 liter of the original sample.
Q2: How to clean a Neubauer improved hemocytometer?
A2: To clean the hemocytometer, first, rinse it with distilled or deionized water. Next, wipe it gently with a lint-free wipe to remove any remaining residue. Finally, rinse it again with water and dry it with compressed air or by allowing it to air dry.
Q3: Can the Neubauer improved hemocytometer be autoclaved?
A3: No, the hemocytometer improved Neubauer cannot be autoclaved because the high temperature and pressure of the autoclave can damage the delicate grid lines and coverslip material.