Source smarter with
Leverage AI to find the perfect product match in seconds
Matches from over 100 million products with precision
Handles queries 3 times as complex in half the time
Verifies and cross-validates product information
Get the app
Get the Alibaba.com app
Find products, communicate with suppliers, and manage and pay for your orders with the Alibaba.com app anytime, anywhere.
Learn more

Mtwo endodontic file

(15 products available)

About mtwo endodontic file

Types of Mtwo Endodontic Files

Endodontic files have multiple variants that serve distinct purposes in the root canal procedure.

  • Flex Files

    Mtwo Flex Files are notable for their flexibility, enabling them to tackle curved root canals without risking fracture or damaging the canal walls. This quality makes them very effective in reaching all parts of complex canal systems. In addition, the files possess a balanced design that guarantees fluidity during the procedure, greatly reducing the chance of procedural errors.

  • Race Files

    Race Files are characteristic for their unique design that allows for rapid canal preparation. These files can remove debris and shape the canal faster than traditional files, thanks to their wider grooves and an efficient thread design. They are especially useful in demanding procedures. In addition, Race Files feature a strong and durable alloy that makes them withstand tough tasks without breaking.

  • Reciproc Files

    Reciproc Files are designed specifically for reciprocating motion systems. They excel in shaping and cleaning the canal with minimal manipulation, saving the dentist time during procedures on complex teeth. Their asynchronous motion is effective in reducing trauma to the canal wall. Also, these files have been tested for safety, possessing the ability to resist metal fatigue in the long run.

  • Stainless Steel Files

    Mtwo also presents classic stainless steel files. Although they have been popular for a long time, they still serve reliable purposes in hand instrumentation. These files are made with high-quality stainless steel and thus are essential for routine endodontic work. They are commonly used in less complex cases.

How to Choose Mtwo Endodontics Files

Buyers visiting Alibaba.com can benefit from several helpful tips when selecting Mtwo Endo files.

  • Choose files based on the endo system

    Different endo files are suitable for distinct systems. For example, Reciproc files are only compatible with systems that employ reciprocating motion. Flex and Race files are intended for traditional hand or motor-driven systems. Buyers must get endo files that are suitable for the systems that their customers prefer.

  • Assess the product's materials

    The material used in manufacturing Mtwo files greatly influences their performance. Most files contain high-quality stainless steel and nickel-titanium alloys. Stainless steel files are strong but rather inflexible. However, nickel-titanium files offer great flexibility and resilience. This property helps them in shaping curved canals. Buyers should also note that premium materials increase biocompatibility and safeguard patients from adverse experiences.

  • Think about the file sets

    Mtwo files come in varying sizes and configurations for different purposes. For instance, some files in a set are meant for initial canal shaping, while others aid in finishing and smoothing. Buyers must consider file sets for endodontic instruments and additional supplies for complete endo kits.

  • File resistance to bending

    Endo files should be resistant to bending and breakage, especially when performing procedures involving curved canals. Endo files that are more resistant to permanent deformation will not only enhance procedural safety but will also require less frequent replacements.

Specifications & Durability of Mtwo Endodontics Files

Durability

Mtwo files are specifically designed to last longer, mainly due to the advanced materials and manufacturing processes involved in their design. For example, files made from proprietary alloys have superior resistance to bending and metal fatigue. Files with enhanced surface treatments have increased hardness and reduced wear. Consequently, these files can provide reliable performance across diverse procedures.

Key specifications

  • Length

    MTwo files come in different lengths but mainly measure 21, 25, and 31 millimeters. Longer files are preferred to provide better access to deeper canals. Conversely, shorter files are more suitable for surface-end procedures that need less exploration. Doctors choosing the file length must consider factors like the location and structure of the targeted tooth.

  • Varied diameters

    Mtwo files are manufactured in varying diameters for different purposes. Generally, larger files in the D0 position are intended for canal apices, while smaller ones at the D10 end are closer to the canal entrance. This variety in diameters makes it possible for doctors to select files according to the condition of the specific tooth.

  • Blade design and surface disposition

    The files have specific helical angles, distances between blades, and surface designs. These properties are responsible for effective irrigation and debris removal. For instance, larger twisted angles result in greater material extraction. In contrast, fine surfaces improve canal smoothness. This attribute makes files more resistant to clogging during procedures.

  • Multiple file types

    There are different types of Mtwo files, such as Flex, Race, and Reciproc files. Mtwo endodontic kits include files for various stages of canal treatment. For example, ready-to-use files are disposable, thus eliminating the need for sterilization between treatments. They are also available in reusable sets, which offer great savings after one purchase.

How to Maintain

  • Proper storage is key

    Mtwo endo files should be placed in a clean and dry environment. They should also be protected from physical damage and extreme temperatures. It is also important for users to distinguish between files intended for single use and those for multiple uses. Only files that are meant for multiple uses should be stored in sterile containers.

  • Sterilization

    Users should strictly follow the sterilization methods recommended by the file manufacturers. In addition, they should ensure that all crevices and blades are properly sterilized to prevent infections. Files should be thoroughly cleaned to remove all organic and inorganic material before sterilization.

  • Regular Inspection

    Endo files should be checked regularly for wear, bending, and other forms of damage. Any defective files should be replaced immediately. Also, multiple-use files should be carefully examined and sterilized after every usage.

  • Sharpening and repair

    Some multi-use Mtwo files can be repaired or sharpened by professionals. Buyers should refer dental experts to repair or sharpen their files. Properly maintained files will perform better and increase patient safety.

How to DIY correctly with Mtwo Endodontics Files

  • Gather all the materials

    Doctors practicing DIY should ensure that they have all the necessary materials. They should prepare the root canal by cleaning and disinfecting the area. Then, they should gather all the needed endo supplies and tools. Lastly, they should ensure they have their Mtwo files in various sizes within easy reach.

  • Initial Kenton access

    Doctors should create an initial access point on the tooth surface for the endodontic instrument. They should use a bur to make a small opening on the surface of the targeted tooth. Then, they should gently insert the endo file into the canal to feel for resistance. They should take caution and ensure they are not forcing the file to go past any bends or curves.

  • Canal exploration

    Doctors should use a gentle twisting motion with the Mtwo file to begin canal exploration and shaping. The files should be turned clockwise and counterclockwise separately to avoid blocking the file. Constant irrigation between measurements is vital for the proper cooling of the files and washing away debris.

  • Canal enlargement

    Doctors should alternate different file sizes as they go deeper into the canal. They should use larger files for the apical portion of the canal and smaller ones near the entrance. They should continue shaping the canal using a gentle twisting motion as they progress to the required working length. The length of the tooth should be measured from the top of the crown to the bottom of the root.

Q&A

Q1. Which materials are the Mtwo files made of, and what do they offer?

A1.MTwo files are made from premium-quality materials such as stainless steel and nickel-titanium alloys. These materials offer flexibility, strength, and biocompatibility. These properties ensure precise canal shaping and resist fracture. Further, these files are well suited to shaping curved canals.

Q2. Are there specific preparations that doctors should do with the files before starting the procedure?

A2.Doctors should ensure that the operating area is well lit and free of distractions. They should organize the Mtwo files according to size and type. Then place them in order of usage. Most files will be handed to doctors, meaning little preparation is needed. However, fight files should be sterilized and cleaned before use.

Q3. What is the role of file design in the Mtwo products offering better performance than others?

A3.The design of Mtwo files incorporates specific features such as unique helical grooves and off-centered twisting. These elements efficiently remove debris while reducing the risk of clogging. In addition, variable tapers facilitate better irrigation. Therefore, these advanced design attributes help achieve optimal shaping without damaging the canal wall.

Q4. When should doctors replace their endo files that are designed for multiple uses?

A4.Doctor's must replace multi-use Mtwo files when they start showing visible signs of wear, such as bending or micro-fractures. Major deterioration of the files can also occur after many uses. Further, any decrease in their performance or difficulty during procedures should prompt users to replace them.