(817 products available)
AlphaSense O2 A2 oxygen sensor is a device used to measure and monitor the levels of oxygen in the environment. There are different types of Alphasense O2 A2 oxygen sensors, including:
The Alphasense O2-A2 sensor specifications are as follows:
Measurement range
The O2-A2 sensor has a measurement range of 0-25% Oxygen. This means that it can measure the concentration of oxygen in the air, from 0 to 25%.
Output signal
The Alphasense O2-A2 sensor has a two-wire current loop output signal. This means that the output signal of the sensor is compatible with most gas detection systems.
Response time
The O2-A2 sensor has a response time of 60 seconds. This means that it takes 60 seconds for the sensor's output signal to reach 90% of the final value after a step change in the oxygen concentration.
Operating temperature
The O2-A2 sensor has an operating temperature of -40 to 65°C. This means that the sensor can operate in extreme temperatures.
Operating pressure
The O2-A2 sensor has a pressure range of 80-120 kPa. This means that the sensor can measure the oxygen concentration in the atmosphere, and its pressure is equivalent to the Earth's sea level.
Dimensions
The O2-A2 sensor has a size of 20x20x7mm. This means that the sensor is small and can be integrated into portable gas detection devices.
Warranty
The Alphasense O2-A2 sensor comes with a 12-month warranty. This means that the manufacturer guarantees that the sensor will work correctly for at least 12 months after purchase, provided that it is used according to the instructions.
Maintaining the Alphasense O2-A2 sensor is crucial to ensure accurate oxygen concentration measurements and prolong its lifespan. Here are some tips on how to take care of the sensor:
Choosing the right AlphaSense O2 A2 oxygen sensor for a project requires careful consideration of several factors. Here are some key points to keep in mind:
First and foremost, consider the sensor's sensitivity. The sensitivity of the sensor determines its ability to detect changes in oxygen levels. Higher sensitivity is preferable for applications that require precise measurements of low oxygen concentrations. On the other hand, less sensitivity is acceptable for general monitoring purposes.
Secondly, select an AlphaSense O2 A2 sensor based on the required response time for the application. Response time refers to the time it takes for the sensor to register a change in oxygen levels. Faster response times are crucial in environments where oxygen levels fluctuate rapidly or in applications that require real-time monitoring.
Additionally, consider the lifespan and stability of the AlphaSense O2 O2 A2 sensors. Some sensors may have a longer lifespan than others, which can reduce the need for frequent replacements and maintenance. Stability ensures consistent and reliable measurements over time, minimizing drift or fluctuations in sensor readings.
Another factor to consider is the operating temperature and range of the AlphaSense O2 A2 sensor. Ensure that the chosen sensor can function optimally within the temperature conditions of the intended application. Additionally, consider the sensor's oxygen concentration range and select one that aligns with the expected levels in the monitored environment.
Furthermore, selecting the right AlphaSense O2 A2 sensor for a project requires careful consideration of the sensor's sensitivity, response time, lifespan, stability, operating temperature, and oxygen concentration range. By carefully evaluating these factors, one can choose an AlphaSense O2 A2 sensor that meets the specific requirements of the intended application, ensuring accurate and reliable oxygen monitoring.
Replacing an Alphasense O2 A2 oxygen sensor can be a straightforward process that can be done by following the manufacturer's instructions. Here is a DIY guide to help replace the sensor:
Tools and Materials Needed:
Step-by-Step Guide:
Safety Precautions:
Q1. How long does the Alphasense O2-A2 last?
A1. The O2-A2 has an expected lifespan of 24 to 36 months. Its lifespan can be affected by different factors, including environmental conditions, exposure to target gases, and operating conditions.
Q2. What is the output signal of the Alphasense O2-A2 A2 sensor?
A2. The Alphasense O2-A2 A2 sensor gives a linear 0.1 to 100 mA output. Users can convert the output to a meaningful concentration value using a suitable signal processing circuit.
Q3. What does the O2-A2 gas sensor detect?
A3. The O2-A2 A2 sensor is used to detect oxygen (O2) levels in the environment. It is not used to detect other gases.
Q4. Can the Alphasense O2-A2 A2 sensor be used for handheld devices?
A4. The Alphasense O2-A2 A2 sensor is designed for general-purpose applications, including portable and handheld devices. However, for specific requirements in handheld devices, users should consult the device's manufacturer or the sensor's datasheet.
Q5. Does the Alphasense O2-A2 A2 sensor require periodic calibration?
A5. Yes, the O2-A2 A2 sensor requires periodic calibration to maintain accuracy. Users should follow the calibration interval and procedure outlined in the sensor's manual.